Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price

Product Details
Customization: Available
Certification: CCC, CE
Working Medium: R410A/R407c/R22
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001, ISO 17025
Terms of Payment
LC, T/T
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
  • Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
Find Similar Products

Basic Info.

Model NO.
HDX-06-H/C
Heat Source Type
Air Source Heat Pump
Color
Whilte/Optional Other Colors
Delivery Time
30days
Tailor Made
Avaiable
OEM/ODM
Avaiable
Capacity
65-130kw
Refrigerant
R22/R407c/R410A/R134A
Compressor Type
Scroll
Transport Package
Film/Wooden Pckage
Trademark
OEM/ODM/HYC
Origin
China
Production Capacity
5000sets

Product Description

Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price                                             
                                          HYC Air to Water Heat Pump System
                                                  A Higher Level of Comfort

           HYC heat pump unit delivers Year-round comfort with exceptional efficiency to design a complete
           Heat pump system for any building.Whether removing heat and humidity from the air to keep you
                                                cool,or drawing heat indoors to keep you warm.


Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
DC Inverter Air Source Heat Pump
DC Inverter heat pump refers to the inverrter compressor.The most common types of compressors are the fixed speed compressor. The fixed speed will run at 100% of its capacity and will stop and start automatically to  maintain the desired temperature. An inverter compressor will vary its speed in order to maintain a consistent temperature. They convert the AC power into DC to all the control of the outdoor unit compressor speed. This gives the unit better accuracy to provide a constant temperature and less energy wastage.

Comparison with non-frequency conversion Heat Pump:
More comfortable
With a wider range of temperatures modes for heating and cooling,the inverter is able to operate in even the most extreme outdoor temperatures.An inverter compressor can also operate faster than non-inverter air conditioners thus allowing the air conditioners to reach the set temperature faster and bring you comfort sooner.

More Comfortable

When the air conditioner is initially activated to either heat or cool,the compressor will operate at maximum speed to reach the desired temperature is achieved,unlike non-inverter air conditioners that turn the compressor on and off,inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised.

More Energy-efficient
Compressor and motor speed in non-inverter type air conditioners remains constant and temperature is adjusted by turning the compressor and more ON and OFF,which consumes more energy.In inverter type air conditioners,temperature is adjusted by changing compressor frequency/motor speed without turning them ON and OFF.Therefor,the power loss of the inverter air conditioner is smaller,with can increase energy efficiency by about 35%.

More Economics
All inverter systems are engineered and manufactured,ensuring performance.reliability,and efficiency.The increased efficiency and operation of our inverter systems reduce the wear tear on the compressor,contributing to durability and longevity of the system.
Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price

FEATURES
CAPACITY RANGE

Capacity ranging from 2.5Ton to 640Ton
Cooling performance: -5~50ºC
Heating performance: -25~24ºC

EASY INSTALLATION
It is supplied as a complete package ready for operation, with no extra controls or other items to be installed. The units have a single power point entry with simple connections.
Quick start-up is assured once installation is completed, as each unit is manufactured in an ISO9001:2000 listed facility to guarantee quality. All units are tested at the factory to provide reliable start up.
Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
HIGHLY QUALITY COMPONENTS AND RELIABLE PERFORMANCE
DC inverter type compressor and high quality world known brand cooling parts, which ensures units' reliable performance.
Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
STRUCTURE
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total
resistance to atmospheric agents.

HERMETIC COMPRESSOR
The units use high efficiency, hermetically sealed, compressors, oil return lubrication and rubber vibration damper. The thermal overload cut-out, phase sequence relay and crankcase heater are integrated as the security
protection to enhance reliability and performance.

AXIAL FAN
External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level
IP54, provided with a protective outlet grille.

EVAPORATOR
Evaporator built with high efficiency plate type heat exchanger, factory insulated with flexible close cell material.

CONDENSER
Condenser built with seamless internal screw thread copper tubes mechanically expanded into blue wave hydrophilic aluminum fins.

HYDRAULIC CIRCUIT
Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.

ELECTRIC PANEL
Electric panel consist of: Compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit) Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

OPTIONAL
• Pressure differential/Flow switch;
• Metallic filter for hydraulic circuit;
• Water pump;
• Rubber anti-vibration mounting..
• BMS
• Stainless steel covering
Model   8 10 12 14 20 25 30 35 40 50
Power supply / 220-240V/1Ph/50Hz 380-415V/3Ph/50Hz
Cooling    
Cooling capacity kW 8 10 12 14 20 25 28 35 40 50
Cooling input power kW 3.05 3.85 4.51 5.13 7.09 8.61 10.05 11.27 13.66 17.18
Heating    
Heating capacity kW 10 12.5 14.7 16 22 27.2 30 38 44 55
Heating input power kW 3.05 3.85 4.51 5.13 7.09 8.61 10.05 11.27 13.66 17.18
Compressor    
Qty / 1 1 1 1 2 2 2 2 2 2
Input power kW 2.81 3.37 4.03 4.65 2x3.27 2x4.03 2x4.65 2x5.26 2x6.28 2x8.04
Running current A 13.12 16.43 7.02 8.32 2x6.26 2x7.02 2x8.32 2x10.03 2x12.01 2x14.79
Axial fan qty / 1 2 2 2 1 1 1 2 2 2
Expansion type / thermal expansion type
Evaporator    
Type / Plate type or tank type heat exchanger
Water flow m3/h 1.4 1.7 2.1 2.4 3.4 4.3 4.8 6.2 6.9 8.6
Water pressure drop kPa 33 33 33 36 36 38 42 50 52 52
Water pipe in/out mm DN25 DN25 DN25 DN25 DN32 DN32 DN32 DN32 DN32 DN40
Dimension    
Length mm 1250 1250 1250 1250 1600 1600 1600 2000 2000 2000
Width mm 452 452 452 452 940 940 940 900 900 900
Height mm 1180 1180 1180 1180 1080 1080 1080 1080 1080 1080
Net weight kg 150 155 150 180 282 310 339 310 470 520
Noise dB(A) 58 58 60 64 64 66 68 70 70 70
  Model   20 30 40
  Power supply V-Ph-Hz 380v/3ph/50hz 380v/3ph/50hz 380v/3ph/50hz
Cooling*    
  cooling capacity KW 65 97.5 130
  cooling power input KW 20.8 31.2 41.6
  cooling current input A 38.50 55.8 74.3
 Heating**    
  heating capacity KW 68 103 141
  heating power input KW 21.5 32.25 43
  heating current input A 38.4 57.6 76.8
 Compressor    
  qty / 2 3 4
  input power kW 10.1*2 10.1*3 10.1*4
  input current A 17.6*2 17.6*3 17.6*4
 Condensor    
  condensor coil qty / 3 4 5
  air flow m3/h 12700*2 17800*2 23800*2
  axial fan qty / 2 2 2
  motor power input KW 0.75*2 1.1*2 1.5*2
 Evaporator    
  type / shell and tube shell and tube shell and tube
  water flow m3/h 11.2 16.8 22.4
  water pressure drop kPa 38 38 38
  water pipe mm DN50 DN50 DN50
  Noise level dB(A) 60 74 78
  Dimension(L*W*H) mm 2020*1000*1920 2020*1000*1920 2020*1000*1920
  Net weight kg 605 830 925

Qingdao Hongyu Cles Air Conditioning Co., Ltd.
Hongyu cles air conditioning(HYC) are dedicated to providing market leading innovations and new technologies that are easy-to-use solutions with the goal to always offer our client reduced energy outlay whilst empowering complete control to customize the solution for their business.

Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
Air Source Heat Pump Production Line

Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
Production Machinery
Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price

Test Lab
Energy Saving DC Inverter Heating and Cooling Air Heat Pump Price
Sincerely welcome to visit our factory at your convience. Customer could witness their order production real conditions by online videos or photos at any time during production.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier