- DC Inverter Technology: Variable speed compressor increases energy efficiency by approximately 35%.
- Customizable Color Options: Available in White or other optional colors upon request.
- Tailor-Made Solutions: OEM and ODM services available with customizable capacity from 8 to 50kW.
- Rapid Delivery: Standard delivery time is 30 days for most orders.
- High-Quality Components: Features hermetically sealed compressors and world-known brand cooling parts.
- Complete Package Installation: Ready for operation with single power entry and no extra controls needed.
- Robust Construction: Galvanized steel panels with polyester powder painting for atmospheric resistance.
Product Attributes
- Customization
- Available
- Certification
- CCC, CE
- Working Medium
- R134A/R410A
- Model NO.
- HCA-C/H
- Heat Source Type
- Air Source Heat Pump
- Color
- Whilte/Optional Other Colors
- Delivery Time
- 30days
- Tailor Made
- Avaiable
- OEM/ODM
- Avaiable
- Capacity
- 8-50kw
- Refrigerant
- R22/R407c/R410A/R134A
- Compressor Type
- Scroll
- Transport Package
- Film/Wooden Package
- Trademark
- OEM/ODM/HYC
- Origin
- China
- Production Capacity
- 5000sets
Product Images of -25 Degree Evi Air to Water Source Heat Pump Heating and Cooling System
Find Similar Products
Product Description
HYC Air to Water Heat Pump System
A Higher Level of Comfort
HYC heat pump unit delivers Year-round comfort with exceptional efficiency to design a complete
Heat pump system for any building.Whether removing heat and humidity from the air to keep you
cool,or drawing heat indoors to keep you warm.
DC Inverter Air Source Heat Pump
DC Inverter heat pump refers to the inverrter compressor.The most common types of compressors are the fixed speed compressor. The fixed speed will run at 100% of its capacity and will stop and start automatically to maintain the desired temperature. An inverter compressor will vary its speed in order to maintain a consistent temperature. They convert the AC power into DC to all the control of the outdoor unit compressor speed. This gives the unit better accuracy to provide a constant temperature and less energy wastage.
Comparison with non-frequency conversion Heat Pump:
With a wider range of temperatures modes for heating and cooling,the inverter is able to operate in even the most extreme outdoor temperatures.An inverter compressor can also operate faster than non-inverter air conditioners thus allowing the air conditioners to reach the set temperature faster and bring you comfort sooner.
More Comfortable
When the air conditioner is initially activated to either heat or cool,the compressor will operate at maximum speed to reach the desired temperature is achieved,unlike non-inverter air conditioners that turn the compressor on and off,inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised.
More Energy-efficient
Compressor and motor speed in non-inverter type air conditioners remains constant and temperature is adjusted by turning the compressor and more ON and OFF,which consumes more energy.In inverter type air conditioners,temperature is adjusted by changing compressor frequency/motor speed without turning them ON and OFF.Therefor,the power loss of the inverter air conditioner is smaller,with can increase energy efficiency by about 35%.
More Economics
All inverter systems are engineered and manufactured,ensuring performance.reliability,and efficiency.The increased efficiency and operation of our inverter systems reduce the wear tear on the compressor,contributing to durability and longevity of the system.
FEATURES
CAPACITY RANGE
Capacity ranging from 2.5Ton to 640Ton
Cooling performance: -5~50ºC
Heating performance: -25~24ºC
EASY INSTALLATION
It is supplied as a complete package ready for operation, with no extra controls or other items to be installed. The units have a single power point entry with simple connections.
Quick start-up is assured once installation is completed, as each unit is manufactured in an ISO9001:2000 listed facility to guarantee quality. All units are tested at the factory to provide reliable start up.
HIGHLY QUALITY COMPONENTS AND RELIABLE PERFORMANCE
DC inverter type compressor and high quality world known brand cooling parts, which ensures units' reliable performance.
STRUCTURE
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total
resistance to atmospheric agents.
HERMETIC COMPRESSOR
The units use high efficiency, hermetically sealed, compressors, oil return lubrication and rubber vibration damper. The thermal overload cut-out, phase sequence relay and crankcase heater are integrated as the security
protection to enhance reliability and performance.
AXIAL FAN
External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level
IP54, provided with a protective outlet grille.
EVAPORATOR
Evaporator built with high efficiency plate type heat exchanger, factory insulated with flexible close cell material.
CONDENSER
Condenser built with seamless internal screw thread copper tubes mechanically expanded into blue wave hydrophilic aluminum fins.
HYDRAULIC CIRCUIT
Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.
ELECTRIC PANEL
Electric panel consist of: Compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit) Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
OPTIONAL
• Pressure differential/Flow switch;
• Metallic filter for hydraulic circuit;
• Water pump;
• Rubber anti-vibration mounting..
• BMS
• Stainless steel covering
| Model | 8 | 10 | 12 | 14 | 20 | 25 | 30 | 35 | 40 | 50 | |
| Power supply | / | 220-240V/1Ph/50Hz | 380-415V/3Ph/50Hz | ||||||||
| Cooling | |||||||||||
| Cooling capacity | kW | 8 | 10 | 12 | 14 | 20 | 25 | 28 | 35 | 40 | 50 |
| Cooling input power | kW | 3.05 | 3.85 | 4.51 | 5.13 | 7.09 | 8.61 | 10.05 | 11.27 | 13.66 | 17.18 |
| Heating | |||||||||||
| Heating capacity | kW | 10 | 12.5 | 14.7 | 16 | 22 | 27.2 | 30 | 38 | 44 | 55 |
| Heating input power | kW | 3.05 | 3.85 | 4.51 | 5.13 | 7.09 | 8.61 | 10.05 | 11.27 | 13.66 | 17.18 |
| Compressor | |||||||||||
| Qty | / | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 |
| Input power | kW | 2.81 | 3.37 | 4.03 | 4.65 | 2x3.27 | 2x4.03 | 2x4.65 | 2x5.26 | 2x6.28 | 2x8.04 |
| Running current | A | 13.12 | 16.43 | 7.02 | 8.32 | 2x6.26 | 2x7.02 | 2x8.32 | 2x10.03 | 2x12.01 | 2x14.79 |
| Axial fan qty | / | 1 | 2 | 2 | 2 | 1 | 1 | 1 | 2 | 2 | 2 |
| Expansion type | / | thermal expansion type | |||||||||
| Evaporator | |||||||||||
| Type | / | Plate type or tank type heat exchanger | |||||||||
| Water flow | m3/h | 1.4 | 1.7 | 2.1 | 2.4 | 3.4 | 4.3 | 4.8 | 6.2 | 6.9 | 8.6 |
| Water pressure drop | kPa | 33 | 33 | 33 | 36 | 36 | 38 | 42 | 50 | 52 | 52 |
| Water pipe in/out | mm | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN32 | DN32 | DN32 | DN40 |
| Dimension | |||||||||||
| Length | mm | 1250 | 1250 | 1250 | 1250 | 1600 | 1600 | 1600 | 2000 | 2000 | 2000 |
| Width | mm | 452 | 452 | 452 | 452 | 940 | 940 | 940 | 900 | 900 | 900 |
| Height | mm | 1180 | 1180 | 1180 | 1180 | 1080 | 1080 | 1080 | 1080 | 1080 | 1080 |
| Net weight | kg | 150 | 155 | 150 | 180 | 282 | 310 | 339 | 310 | 470 | 520 |
| Noise | dB(A) | 58 | 58 | 60 | 64 | 64 | 66 | 68 | 70 | 70 | 70 |
| Model | 20 | 30 | 40 | ||
| Power supply | V-Ph-Hz | 380v/3ph/50hz | 380v/3ph/50hz | 380v/3ph/50hz | |
| Cooling* | |||||
| cooling capacity | KW | 65 | 97.5 | 130 | |
| cooling power input | KW | 20.8 | 31.2 | 41.6 | |
| cooling current input | A | 38.50 | 55.8 | 74.3 | |
| Heating** | |||||
| heating capacity | KW | 68 | 103 | 141 | |
| heating power input | KW | 21.5 | 32.25 | 43 | |
| heating current input | A | 38.4 | 57.6 | 76.8 | |
| Compressor | |||||
| qty | / | 2 | 3 | 4 | |
| input power | kW | 10.1*2 | 10.1*3 | 10.1*4 | |
| input current | A | 17.6*2 | 17.6*3 | 17.6*4 | |
| Condensor | |||||
| condensor coil qty | / | 3 | 4 | 5 | |
| air flow | m3/h | 12700*2 | 17800*2 | 23800*2 | |
| axial fan qty | / | 2 | 2 | 2 | |
| motor power input | KW | 0.75*2 | 1.1*2 | 1.5*2 | |
| Evaporator | |||||
| type | / | shell and tube | shell and tube | shell and tube | |
| water flow | m3/h | 11.2 | 16.8 | 22.4 | |
| water pressure drop | kPa | 38 | 38 | 38 | |
| water pipe | mm | DN50 | DN50 | DN50 | |
| Noise level | dB(A) | 60 | 74 | 78 | |
| Dimension(L*W*H) | mm | 2020*1000*1920 | 2020*1000*1920 | 2020*1000*1920 | |
| Net weight | kg | 605 | 830 | 925 | |
Qingdao Hongyu Cles Air Conditioning Co., Ltd.
Hongyu cles air conditioning(HYC) are dedicated to providing market leading innovations and new technologies that are easy-to-use solutions with the goal to always offer our client reduced energy outlay whilst empowering complete control to customize the solution for their business.

Air Source Heat Pump Production Line
Production Machinery
Test Lab
Sincerely welcome to visit our factory at your convience. Customer could witness their order production real conditions by online videos or photos at any time during production.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2351520". Items marked "" are certified.
Company Profile
Qingdao HongYu Cles Air Conditioning Co., Ltd. Established in 1999, specializes in the R&D, manufacturing, sales and after services of central air conditioner products.
By professional manufacturing for over 17 years, our product line covers air cooled mini type & air cooled modular type chiller (heat pump), water cooled mini type & water cooled modular type chiller (heat pump), air cooled screw type & water cooled screw type chiller (heat pump), DX type rooftop packaged unit & ducted split unit, water cooled air chiller (heat pump), air handling unit (water chilled & DX type), fan coil unit (concealed & exposed), fan heater etc.
With quality product and professional service, our customer group includes government building, office building, stadium, hotel, exhibition center, hospital, industrial products manufacturing factory, pharmacy factory, supermarket, automobile factory, mine industry, museum etc.
HongYu is a member of China professional committee of central heating and heat measurement, and a member of China Shandong Association of Refrigeration. With numerous patents technology, and hold certificates like "High-tech product", " specialized, superior, peculiar and new area", ISO, CQC, CCC, OHSAS etc, HongYu could offer intelligent solutions to customers.
By continuous quality improving, we guarantee the clients high quality products, and maintain a healthy, stable and sustainable development.
Chose Hongyu product, chose a better life.
About Our Factory & Business Background
- Address
- No. 5 Shengda Road, Tonghe Industrial Zone, Pingdu, Qingdao, Shandong, China
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Main Markets
- South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- Is the product color customizable?
- Yes, the standard color is White, but other optional colors are available.
- Do you offer OEM and ODM services?
- Yes, tailor-made solutions, OEM, and ODM services are available.
- What is the delivery time for this heat pump?
- The standard delivery time is 30 days.
- What refrigerants are supported by this system?
- The system supports R134A, R410A, R22, and R407c refrigerants.
- How does the DC Inverter technology improve efficiency?
- It adjusts compressor speed to maintain constant temperature, increasing energy efficiency by about 35%.
- What certifications does the product have?
- The product holds CCC and CE certifications.
- What is the capacity range of the heat pump?
- The capacity ranges from 2.5 Ton to 640 Ton, with specific models from 8kW to 50kW.
Send your message to this supplier
People who viewed this also viewed
-
US$500.00-999.00 / Piece
-
US$1,000.00-4,000.00 / Piece
-
US$500.00-999.00 / Piece
-
US$500.00-2,000.00 / Piece
-
US$1,750.00-8,500.00 / Piece
-
US$8,000.00-100,000.00 / Piece
-
US$5,000.00-20,000.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Air cooled water chiller&heat pump
- -25 Degree Evi Air to Water Source Heat Pump Heating and Cooling System
Related Categories
Hot Searches
- Pump Controller Factories
- Electrical Pump Factories
- Heat Switch Factories
- Heat Shrink Tube Factories
- Water Pump Controller
- Electrical Air Pump
- Ac Electric Air Pump
- 30 Kw Heat Pump
- Water Pump Sensor
- Air Conditioner Bulkbuy